Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Assessment of Ventilation I: Respiratory Rate01:20

Assessment of Ventilation I: Respiratory Rate

1.1K
Assessment of Ventilation
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
1.1K
Pulse rhythm01:30

Pulse rhythm

798
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
798
Special considerations while measuring oxygen saturation01:19

Special considerations while measuring oxygen saturation

592
Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
592
Assessment of Diffusion and Perfusion01:17

Assessment of Diffusion and Perfusion

979
Understanding and evaluating diffusion and perfusion is critical in assessing a patient's respiratory and circulatory health. These processes play key roles in maintaining the body's internal environment, ensuring that tissues receive adequate oxygen while waste products are efficiently removed.
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
979
Respiratory Volumes and Capacities I01:26

Respiratory Volumes and Capacities I

1000
Assessing the respiratory rate and rhythm for a complete minute is crucial for evaluating the breathing pattern. Even a minor increase in the patient's average respiratory rate, by as little as three to five breaths per minute, is an early and vital indicator of respiratory distress. Patients with a respiratory rate exceeding twenty-four breaths per minute require close monitoring to determine the physiological alterations. This careful observation is essential for prompt recognition and...
1000
Assessment of Airway, Skin Color, and Use of Accessory Muscles01:30

Assessment of Airway, Skin Color, and Use of Accessory Muscles

999
A thorough assessment of respiratory health is paramount in clinical settings to identify and manage respiratory distress and ensure adequate oxygenation. This article elaborates on the critical aspects of respiratory evaluation, including airway assessment, skin color examination, and the observation of accessory muscle use, which are integral to effectively diagnosing and managing patients with respiratory conditions.
Introduction
The initial evaluation of a patient's respiratory system...
999

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Multisite Mobile Addiction Services: Four-Year Outcomes.

International journal of environmental research and public health·2026
Same author

Self-Maintaining Electrode-Skin Interface for Motion-Robust Biosignal Monitoring.

Advanced healthcare materials·2026
Same author

"We're All in This Together": A Mixed-Methods Study of Provider and Patient Perceptions of Emergency Care for Opioid Use Disorder.

Journal of advanced nursing·2026
Same author

Patient Perceptions on Opioid Therapy for Acute Pain Management in the Emergency Department and Post-Surgical Settings: A Qualitative Study.

Journal of pain research·2025
Same author

Leveraging Trauma Informed Care for Digital Health Intervention Development in Opioid Use Disorder.

Journal of medical toxicology : official journal of the American College of Medical Toxicology·2024
Same author

Detection of ethanol, cannabinoids, benzodiazepines, and opioids in older adults evaluated for serious injuries from falls.

Clinical toxicology (Philadelphia, Pa.)·2024

Related Experiment Video

Updated: Jul 2, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
07:51

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor

Published on: September 29, 2020

8.8K

Contactless Monitoring System Versus Gold Standard for Respiratory Rate Monitoring in Emergency Department Patients:

Charlotte E Goldfine1, Md Farhan Tasnim Oshim2, Brittany P Chapman3

  • 1Division of Medical Toxicology, Department of Emergency Medicine, Brigham and Women's Hospital, Boston, MA, United States.

JMIR Formative Research
|February 16, 2024
PubMed
Summary

This study evaluated a contactless radar sensor for respiratory rate monitoring. While not statistically significant, the PulsON 440 (P440) radar showed improved agreement at normal respiratory rates, indicating potential for future clinical use.

Keywords:
cardiopulmonary monitoringcontactless monitorradarrespiratory ratevital signs

More Related Videos

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
07:52

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department

Published on: January 29, 2011

16.2K
Conducting Respiratory Oscillometry in an Outpatient Setting
14:49

Conducting Respiratory Oscillometry in an Outpatient Setting

Published on: April 8, 2022

7.1K

Related Experiment Videos

Last Updated: Jul 2, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
07:51

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor

Published on: September 29, 2020

8.8K
Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
07:52

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department

Published on: January 29, 2011

16.2K
Conducting Respiratory Oscillometry in an Outpatient Setting
14:49

Conducting Respiratory Oscillometry in an Outpatient Setting

Published on: April 8, 2022

7.1K

Area of Science:

  • Biomedical Engineering
  • Medical Devices
  • Respiratory Physiology

Background:

  • Respiratory rate is a critical, yet often neglected, vital sign.
  • Current monitoring methods are labor-intensive and prone to inaccuracies.
  • Contactless monitoring solutions are needed for improved patient assessment.

Purpose of the Study:

  • To compare the PulsON 440 (P440) radar module against manual and telemetry monitoring for respiratory rate.
  • To assess P440 radar agreement with gold standard measurements across different patient subgroups.

Main Methods:

  • A pilot study involving 14 adult emergency department patients.
  • Continuous 2-hour monitoring with the P440 radar module.
  • Comparison of P440 data with manual counts and telemetry at 15-minute intervals using Bland-Altman plots and ICC.

Main Results:

  • The P440 radar showed a bias of -0.76 and an intraclass correlation coefficient (ICC) of 0.38 compared to the gold standard.
  • Agreement between P440 and gold standard was highest within the normal physiologic respiratory rate range.
  • No significant differences in agreement were observed based on sex or admitting diagnosis.

Conclusions:

  • The P440 radar demonstrated a trend towards better agreement at normal respiratory rates, with overestimation at low and underestimation at high rates.
  • Future model adjustments are needed to enhance accuracy in detecting respiratory rates.
  • Validated contactless radar technology offers a promising solution for continuous patient monitoring.