A wearable gait-analysis device for idiopathic normal-pressure hydrocephalus (INPH) monitoring
Erdem Atbas1, Patrick Gaydecki2, Michael J Callaghan3
1The Department of Electrical and Electronics and School of Health Sciences, The University of Manchester, Manchester, M13 9PY, United Kingdom.
Abstract:
Idiopathic Normal Pressure Hydrocephalus (iNPH) is a progressive neurologic disorder (fluid build-up in the brain) that affects 0.2%-5% of the UK population aged over 65. Mobility problems, dementia and urinary incontinence are symptoms of iNPH but often these are not properly evaluated, and patients receive the wrong diagnosis. Here, we describe the development and testing of firmware embedded in a wearable device in conjunction with a user-based software system that records and analyses a patient's gait. The movement patterns, expressed as quantitative data, allow clinicians to improve the non-invasive assessment of iNPH as well as monitor the management of patients undergoing treatment. The wearable sensor system comprises a miniature electronic unit that attaches to one ankle of the patient via a simple Velcro strap which was designed for this application. The unit monitors acceleration along three axes with a sample rate of 60 Hz and transmits the data via a Bluetooth communication link to a tablet or smart phone running the Android and the iOS operating systems. The software package extracts statistics based on stride length, stride height, distance walked and speed. Analysis confirmed that the system achieved an average accuracy of at least 98% for gait tests conducted over distances 9 m. This device has been developed to assist in the management and treatment of older adults diagnosed with iNPH.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pressure Gauges
Measurement of Blood Pressure