Related Experiment Video
Updated: Jul 10, 2026

Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
Published on: September 21, 2018
Reliability and validity of a non-linear index of heart rate variability to determine intensity thresholds
Noemí Sempere-Ruiz1,2, José Manuel Sarabia1,2, Sabina Baladzhaeva1,2
1Department of Sport Sciences, Sport Research Centre, Miguel Hernandez University, Elche, Spain.
Abstract:
Exercise intensity distribution is crucial for exercise individualization, prescription, and monitoring. As traditional methods to determine intensity thresholds present limitations, heart rate variability (HRV) using DFA a1 has been proposed as a biomarker for exercise intensity distribution. This index has been associated with ventilatory and lactate thresholds in previous literature. This study aims to assess DFA a1's reliability and validity in determining intensity thresholds during an incremental cycling test in untrained healthy adults. Sixteen volunteers (13 males and 3 females) performed two identical incremental cycling stage tests at least 1 week apart. First and second ventilatory thresholds, lactate thresholds, and HRV thresholds (DFA a1 values of 0.75 and 0.5 for HRVT1 and HRVT2, respectively) were determined in heart rate (HR), relative oxygen uptake (VO2rel), and power output (PO) values for both tests. We used intraclass correlation coefficient (ICC), change in mean, and typical error for the reliability analysis, and paired t-tests, correlation coefficients, ICC, and Bland-Altman analysis to assess the agreement between methods. Regarding reliability, HRV thresholds showed the best ICCs when measured in PO (HRVT1: ICC = .87; HRVT2: ICC = .97), comparable to ventilatory and lactate methods. HRVT1 showed the strongest agreement with LA 2.5 in PO (p = 0.09, r = .93, ICC = .93, bias = 9.9 ± 21.1), while HRVT2 reported it with VT2 in PO (p = 0.367, r = .92, ICC = .92, bias = 5.3 ± 21.9). DFA a1 method using 0.75 and 0.5 values is reliable and valid to determine HRV thresholds in this population, especially in PO values.
More Related Videos
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Reliability and Validity
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...