Related Experiment Video
Updated: Jul 2, 2025

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Heart Rate Variability Thresholds: Agreement with Established Approaches and Reproducibility in Trained Females and
Pablo R Fleitas-Paniagua1, Gabriele Marinari1, Letizia Rasica1
1Faculty of Kinesiology, University of Calgary, Calgary, CANADA.
Purpose:
To determine in trained females and males i) the agreement between the gas exchange threshold (GET), lactate threshold 1 (LT1), and heart rate variability threshold 1 (HRVT1), as well as between the respiratory compensation point (RCP), lactate threshold 2 (LT2), and heart rate variability threshold 2 (HRVT2), and ii) the reproducibility of HRVT1 and HRVT2 during 2-min incremental step protocols.
Methods:
Fifty-seven trained participants (24 females) completed a 2-min step incremental test to task failure. Nineteen participants (eight females) completed a second test to evaluate reproducibility. Gas exchange and ventilatory responses, blood lactate concentration, and RR time series were recorded to assess the oxygen consumption (V̇O 2 ) and heart rate (HR) associated with the GET, RCP, LT1, LT2, HRVT1, and HRVT2.
Results:
V̇O 2 -GET versus V̇O 2 -HRVT1 and HR-GET versus HR-HRVT1 were statistically different for females (29.5 ± 4.0 vs 34.6 ± 6.1 mL·kg -1 ·min -1 ; 154 ± 11 vs 166 ± 12 bpm) and for males (33.9 ± 4.2 vs 42.7 ± 4.6 mL·kg -1 ·min -1 ; 145 ± 11 vs 165 ± 9 bpm; P < 0.001). V̇O 2 and HR at HRVT1 were greater than at LT1 ( P < 0.05). V̇O 2 -RCP versus V̇O 2 -HRVT2 and HR-RCP versus HR-HRVT2 were not statistically different for females (40.1 ± 4.7 vs 39.5 ± 6.7 mL·kg -1 ·min -1 ; 177 ± 9 vs 176 ± 9 bpm) and males (48.4 ± 5.4 vs 47.8 ± 4.8 mL·kg -1 ·min -1 ; 176 ± 8 vs 175 ± 9 bpm; P > 0.05). V̇O 2 and HR responses at LT2 were similar to HRVT2 ( P > 0.05). Intraclass correlation coefficient for V̇O 2 -HRVT1, HR-HRVT1, V̇O 2 -HRVT2, and HR-HRVT2 indicated good reproducibility when comparing the two different time points to standard methods.
Conclusions:
Whereas HRVT2 is a valid and reproducible estimate of the RCP/LT2, current approaches for HRVT1 estimation did not show good agreement with outcomes at GET and LT1.
More Related Videos
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Regulation of Pulse
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Assessment of blood pressure in brachial artery(two-step method)
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

