Related Experiment Video
Updated: Jul 2, 2025

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Clinical decision support system using a machine learning model to assist simultaneous cardiopulmonary auscultation:
Takanobu Hirosawa1, Tetsu Sakamoto1, Yukinori Harada1
1Department of Diagnostic and Generalist Medicine, Dokkyo Medical University, Tochigi, Japan.
Background:
The utility of a clinical decision support system using a machine learning (ML) model for simultaneous cardiac and pulmonary auscultation is unknown.
Objective:
This study aimed to develop and evaluate an ML system's utility for cardiopulmonary auscultation.
Methods:
First, we developed an ML system for cardiopulmonary auscultation, using cardiopulmonary sound files from our previous study. The technique involved pre-processing, feature extraction, and classification through several neural network layers. After integration, the output class was categorized as "normal," "abnormal," or "undetermined." Second, we evaluated the ML system with 24 junior residents in an open-label randomized controlled trial at a university hospital. Participants were randomly assigned to the ML system group (intervention) or conventional auscultation group (control). During training, participants listened to four cardiac and four pulmonary sounds, all of which were correctly classified. Then, participants classified a series of 16 simultaneous cardiopulmonary sounds. The control group auscultated the sounds using noise-cancelling headphones, while the intervention group did so by watching recommendations from the ML system.
Results:
The total scores for correctly identified normal or abnormal cardiopulmonary sounds in the intervention group were significantly higher than those in the control group (366/384 [95.3%] vs. 343/384 [89.3%], P = 0.003). The cardiac test score in the intervention group was better (111/192 [57.8%] vs. 90/192 [46.9%], P = 0.04); there was no significant difference in pulmonary auscultation.
Conclusions:
The ML-based system improved the accuracy of cardiopulmonary auscultation for junior residents. This result suggests that the system can assist early-career physicians in accurate screening.