Related Experiment Video
Updated: Jul 2, 2025

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Cutting efficiency and corrosion resistance of heat-treated endodontic files after various disinfection protocols
Seyma Ulusoy1, Fatima Betül Basturk2, Dilek Turkaydın1
1Department of Endodontics, Faculty of Dentistry, Marmara University, Başıbüyük Yolu Marmara Üniversitesi Başıbüyük Sağlık Yerleşkesi 9/3, Başıbüyük, Maltepe, P.O. Box: 34854, Istanbul, Turkey.
Abstract:
The aim of this study is to evaluate the effect of various disinfection protocols on the cutting efficiency and chemical composition of ProTaper, Twisted File, Twisted File Adaptive, and Hedström files. Four experimental groups (n = 10) were presoaked in either enzymatic solution or 1% sodium hypochlorite for 30 min, followed by either 5 or 15 min of ultrasonic cleaning and then autoclaved. Resin-simulated canals with a single curvature of 38-40° were prepared by each instrument system. Cutting efficiency of each instrument was analyzed by subtracting the final weight from the initial weight of the resin blocks. Chemical compositions were studied by field emission scanning electron microscopy and X-ray energy-dispersive spectrometry. The cutting efficiency of Hedström, ProTaper, and Twisted File instruments decreased compared to their control groups (p < 0.05) whereas it did not change for Twisted File Adaptive. More corrosion was detected with longer ultrasonication time. No difference was observed regarding the pre-soaking media. Disinfection protocols exerted a significant overall effect on the performance of Hedström, ProTaper, and Twisted File instruments. Corrosion, microcracks, and crevices were evident on all tested instruments after disinfection protocols applied. All disinfection protocols, regardless of the pre-soaking media used or the ultrasonic cleaning time applied, have some effect on the cutting efficiency and the surface characteristics of the files.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...