Related Experiment Video
Updated: Jul 30, 2026

Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
Validity and reliability of the Oura Ring Generation 3 (Gen3) with Oura sleep staging algorithm 2.0 (OSSA 2.0) when
Thomas Svensson1, Kaushalya Madhawa2, Hoang Nt2
1Precision Health, Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; Graduate School of Health Innovation, Kanagawa University of Human Services, Kawasaki-ku, Kawasaki-shi, Kanagawa, Japan; Department of Clinical Sciences, Lund University, Skåne University Hospital, Malmö, Sweden.
Purpose:
To evaluate the validity and the reliability of the Oura Ring Generation 3 (Gen3) with Oura Sleep Staging Algorithm 2.0 (OSSA 2.0) through multi-night polysomnography (PSG).
Participants And Methods:
Participants were 96 generally healthy Japanese men and women aged between 20 and 70 years contributing with 421,045 30-s epochs. Sleep scoring was performed according to American Academy of Sleep Medicine criteria. Each participant could contribute with a maximum of three polysomnography (PSG) nights. Within-participant means were created for each sleep measure and paired t-tests were used to compare equivalent measures obtained from the PSG and Oura Rings (non-dominant and dominant hand). Agreement between sleep measures were assessed using Bland-Altman plots. Interrater reliability for epoch accuracy was determined by prevalence-adjusted and bias-adjusted kappa (PABAK).
Results:
The Oura Ring did not significantly differ from PSG for the measures time in bed, total sleep time, sleep onset latency, sleep period time, wake after sleep onset, time spent in light sleep, and time spent in deep sleep. Oura Rings worn on the non-dominant- and dominant-hand underestimated sleep efficiency by 1.1 %-1.5 % and time spent in REM sleep by 4.1-5.6 min. The Oura Ring had a sensitivity of 94.4 %-94.5 %, specificity of 73.0 %-74.6 %, a predictive value for sleep of 95.9 %-96.1 %, a predictive value for wake of 66.6 %-67.0 %, and accuracy of 91.7 %-91.8 %. PABAK was 0.83-0.84 and reliability was 94.8 %. Sleep staging accuracy ranged between 75.5 % (light sleep) and 90.6 % (REM sleep).
Conclusions:
The Oura Ring Gen3 with OSSA 2.0 shows good agreement with PSG for global sleep measures and time spent in light and deep sleep.
More Related Videos
08:20Measuring Neural Mechanisms Underlying Sleep-Dependent Memory Consolidation During Naps in Early Childhood
Published on: October 2, 2019
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Blind Procedures
Stages of Sleep
Before sleep begins, in wakefulness, the brain exhibits primarily beta waves, which are high in frequency and low in amplitude, indicating alertness...