Related Experiment Video
Updated: Jun 21, 2026

2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
Effect of soft denture liners on complete denture treatments: A systematic review
Yoko Hasegawa1, Hajime Minakuchi2, Masahiro Nishimura3
1Division of Comprehensive Prosthodontics, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan.
Purpose:
This systematic review examined the effectiveness of soft denture relining (SDR) materials.
Study Selection:
A comprehensive search of MEDLINE, Cochrane Library, and ICHUSHI was conducted up to July 26, 2020. Target outcomes were patient satisfaction, oral health-related quality of life (OHRQOL), masticatory ability (MA), denture functional duration, residual ridge resorption (RRR), and microbial contamination. An organization specializing in literature searches performed the reference searches, and two reviewers independently selected the literature sources, extracted the data, and assessed the risk of bias. The reviewers resolved any disagreements concerning the assortment of literature sources through discussion. SDR included acrylic- and silicone-based materials, which were evaluated separately.
Results:
Reviewers selected 7, 5, 11, 1, 4, and 6 studies to assess patient satisfaction, OHRQOL, MA, functional duration, RRR, and microbial contamination, respectively. The results confirmed that SDR improved patient satisfaction, OHRQOL, MA, and RRR. However, the functional duration of SDR material is shorter than that of hard denture relining (HDR) or acrylic resin material. Furthermore, SDR material is more susceptible to microbial contamination in the long term. The risk of bias for the included studies tended to be high because of specific issues (difficulty in blinding SDR versus HDR).
Conclusions:
For patients who wear complete dentures, SDR often provides beneficial outcomes such as pain reduction and recovery from MA. However, caution should be exercised regarding their use owing to insufficient functional duration and the possibility of microbial contamination during long-term use.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025