Background:
Diagnosis of foveal triangular fibrocartilage complex (TFCC) tears remains difficult. The purpose of this study was to evaluate whether dynamic computed tomography (CT) of the distal radioulnar joint (DRUJ) has a higher sensitivity in detecting foveal tears of the TFCC when compared with magnetic resonance imaging (MRI).
Methods:
A database query identified all patients above the age of 18 years with suspected foveal TFCC injuries who underwent bilateral dynamic CT imaging of the DRUJ, static 3T MRI, and subsequent wrist arthroscopy. All patients had evidence of foveal tenderness on clinical examination. The imaging results were validated with wrist arthroscopy.
Results:
Twelve patients with a mean age of 31 years (range, 18-53 years) were identified. Eight patients were diagnosed with a complete foveal detachment of the TFCC on wrist arthroscopy. Of the 8 patients with a foveal tear on DRUJ arthroscopy, only 3 had a preoperative physical examination suggestive of DRUJ instability. Magnetic resonance imaging identified foveal injuries in 4 of these 8 patients (sensitivity, 50%), and 3 of these were identified as only partial tears. Dynamic CT identified instability of DRUJ in 6 of 8 patients (sensitivity, 75%). Seven of 8 patients had imaging findings suggestive of a foveal tear when including either MRI or CT imaging (sensitivity, 88%). Of the 4 patients with an intact foveal attachment on arthroscopy, 3 (specificity, 75%) had a stable DRUJ on CT and all 4 (specificity, 100%) had an intact foveal attachment on MRI.
Conclusion:
Sixty-two percent of patients with foveal tears on arthroscopy have a stable DRUJ on clinical examination. When combining MRI and dynamic CT imaging of the DRUJ, the sensitivity of detecting a foveal TFCC tear approaches 88% compared with a gold standard of wrist arthroscopy.
More Related Videos
07:06Use of Micro X-ray Computed Tomography with Phosphotungstic Acid Preparation to Visualize Human Fibromuscular Tissue
Published on: September 5, 2019
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...