System stability and signal enhancement with analyte protectants: Gas chromatography analysis of
Mathias B Jørgensen1, Peter P Nyemann2, Inam U Haq2
1Department of Plant and Environmental Sciences, University of Copenhagen, Thorvaldsensvej 40, 1871, Frederiksberg C, Denmark; BIOFOS A/S, Refshalevej 250, 1432, København, Denmark; MSCi, Bøgesvinget 8, 2740, Skovlunde, Denmark.
Abstract:
Matrix effects can affect detection limits, precision, and accuracy and lead to signal enhancement or suppression effects in gas chromatography analysis. Analyte protectants, such as shikimic acid and gluconolactone, can imitate the effect of matrix components and reduce the differences in matrix effect between samples. This study aimed to investigate the ability of analyte protectants to enhance gas chromatography detector signals of different oxygenated-polycyclic aromatic hydrocarbons. Addition of 100 μg L-1 shikimic acid and 200 μg L-1 gluconolactone effectively enhanced detector response of the investigated target compounds. Addition of a higher content of analyte protectants did not result in any further enhancement. It was found that between four and eleven consecutive injections of a standard solution with analyte protectants were required to obtain a stable compound response. The long-term signal stability was then maintained with subsequent injections, though an overall negative drift of the system was observed over the sequence of 200 investigated injections. Analysis of the actual sample matrix instead of standards in pure solvent, as presented in this study, could also be a way to minimize the required number of injections. Shikimic acid and gluconolactone were first and foremost able to enhance signals of oxygenated-polycyclic aromatic hydrocarbons with similar functional groups (hydroxyl) in their molecular structure. It can be relevant to consider alternative analyte protectants with different functional groups according to the type of target compounds investigated.
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...