Accuracy in clinical laboratories participating in regional quality control programs
This study assessed analytic bias in clinical chemistry labs using quality control data. All-methods results showed good agreement with benchmark methods for key analytes, suggesting their utility in future quality control programs.
Area of Science:
- Clinical Chemistry
- Laboratory Medicine
- Quality Control
Background:
- Analytic bias (accuracy) in clinical chemistry laboratories is understudied.
- Quality control programs are essential for maintaining laboratory accuracy.
Purpose of the Study:
- To assess the analytic bias of participant "all-methods" results and individual methods for key analytes.
- To evaluate the agreement between "all-methods" results and established benchmark methods.
Main Methods:
- Utilized a six-year dataset from a large regional quality control program.
- Compared participant "all-methods" results and individual methods against United States Bureau of Standards definitive methods and/or United States Centers for Disease Control clinical reference methods.
- Analyzed bias for calcium, cholesterol, glucose, potassium, and sodium at clinically relevant levels.
Main Results:
- "All-methods" bias was found to be +0.1% for calcium, -0.7% for cholesterol, +4.5% for glucose, +0.5% for potassium, and 0% for sodium at specified concentrations.
- Sufficient agreement was observed between benchmark and "all-methods" results for these analytes.
Conclusions:
- "All-methods" results demonstrate acceptable analytic bias when compared to definitive and reference methods.
- "All-methods" results can serve as effective analytic bias benchmarks in future regional quality control programs.
- The findings support the reliability of aggregated laboratory data for assessing accuracy.
More Related Videos
07:52Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
Published on: September 10, 2018
07:43A Validatable Droplet Digital Polymerase Chain Reaction Assay for the Detection of Adeno-Associated Viral Vectors in Bioshedding Studies of Tears
Published on: July 14, 2023
Related Concept Videos
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance
Data Validation
Key parameters for method validation include:
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Automated Microbial Diagnostics