A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Disinfection of central venous access device needleless connectors: A human factors analysis
Frank A Drews1, Richard A Martinello2,3, Joan N Hebden4
1Department of Psychology, University of Utah, Salt Lake City, Utah.
Objective:
Evidence-based central-line-associated bloodstream infection (CLABSI) prevention guidelines recommend the use of an antiseptic scrub to disinfect needleless connectors before device access. Guideline noncompliance may render disinfection ineffective. The goal of this study was to observe needleless-connector disinfection practices and to identify perceived facilitators and barriers to best practices of needleless-connector access.
Methods:
A human factors mixed-methods study involving nursing focus groups of perceived barriers and facilitators and clinical observations of compliance with instructions and protocols for use of 3.15% chlorhexidine gluconate/70% isopropyl alcohol (CHG/IPA) and 70% isopropyl alcohol (IPA) antisepsis products for central venous access device (CVAD) needleless-connector disinfection was conducted in intensive care units (ICUs) at 2 academic medical centers.
Results:
Access to the antiseptic product and lesser workload were identified as best-practice facilitators. Barriers were the time required per needleless-connector access and knowledge deficits. Of the 48 observed access events, 77% resulted in needleless-connector disinfection. The observed mean needleless-connector scrubbing times when using IPA were substantially below the recommended time. Drying time after product use was negligible.
Conclusions:
Lack of access to the disinfection product, emergency situations, and high workload were barriers to needleless-connector disinfection. Observed scrubbing and drying times were shorter than recommended, especially for IPA wipes. These needleless-connector disinfection deficits may increase the risk of CLABSI. Ongoing education and periodic competency evaluation of needleless-connector disinfection, improvement of supply management, and staffing workload are required to imbed and sustain best practices. Further study involving a larger sample size in diverse patient populations is warranted.
More Related Videos
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Hand hygiene
Hand washing...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...