Related Experiment Video
Updated: Jul 2, 2025

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Comparative analysis of novel heat-treated retreatment file system on the removal of obturating material using
Sruthi Sairaman1, Pradeep Solete1, Ganesh Jeevanandan2
1Department of Conservative Dentistry and Endodontics, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
Introduction:
The aim of nonsurgical retreatment is to remove the previous filling material followed by chemo-mechanical preparation of the canal to achieve proper disinfection of the root canal system. This is then followed by re-obturation. This study evaluates the time taken to retrieve the gutta-percha and the quantity of remaining filling material after retreatment with two different file systems. The quantity of remaining filling material was assessed using nano-computed tomography (CT) due to its increased accuracy.
Materials And Methods:
Forty extracted single-rooted teeth were split into two groups at random and decoronated and obturated at a standard root length of 16 mm. Solite RS3 (SRS-3) Retreatment and ProTaper Universal Retreatment (PTUR) systems were used to retrieve the gutta-percha after a preoperative nano-CT scan. Postoperative nano-CT scan was taken and both the scans were superimposed to quantify the remaining filling material. The time taken to remove gutta-percha was measured using a stopwatch. The statistical analysis comparing the two groups was conducted using the independent t-test.
Results:
The quantitative analysis of remaining filling material using nano-CT showed no statistical difference between both the file systems used (P > 0.05). However, SRS-3 took significantly less time in the removal of gutta-percha (P < 0.05).
Conclusion:
Hence, we can conclude that there is no significant difference in the amount of remaining filling material between both the file systems. However, time taken to remove the gutta-percha was lesser in SRS-3 compared to PTUR file system.
More Related Videos
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019