Related Experiment Video
Updated: May 5, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Performance of a Machine Learning Algorithm to Predict Hypotension in Spontaneously Breathing Non-Ventilated
Johan T M Tol1, Lotte E Terwindt1, Santino R Rellum1,2
1Department of Anesthesiology, University of Amsterdam, Amsterdam UMC, Meibergdreef 9, 1105AZ Amsterdam, The Netherlands.
Abstract:
Background: Hypotension is common in the post-anesthesia care unit (PACU) and intensive care unit (ICU), and is associated with adverse patient outcomes. The Hypotension Prediction Index (HPI) algorithm has been shown to accurately predict hypotension in mechanically ventilated patients in the OR and ICU and to reduce intraoperative hypotension (IOH). Since positive pressure ventilation significantly affects patient hemodynamics, we performed this validation study to examine the performance of the HPI algorithm in a non-ventilated PACU and ICU population. Materials & Methods: The performance of the HPI algorithm was assessed using prospectively collected blood pressure (BP) and HPI data from a PACU and a mixed ICU population. Recordings with sufficient time (≥3 h) spent without mechanical ventilation were selected using data from the electronic medical record. All HPI values were evaluated for sensitivity, specificity, predictive value, and time-to-event, and a receiver operating characteristic (ROC) curve was constructed. Results: BP and HPI data from 282 patients were eligible for analysis, of which 242 (86%) were ICU patients. The mean age (standard deviation) was 63 (13.5) years, and 186 (66%) of the patients were male. Overall, the HPI predicted hypotension accurately, with an area under the ROC curve of 0.94. The most used HPI threshold cutoff in research and clinical use, 85, showed a sensitivity of 1.00, specificity of 0.79, median time-to-event of 160 s [60-380], PPV of 0.85, and NPV of 1.00. Conclusion: The absence of positive pressure ventilation and the influence thereof on patient hemodynamics does not negatively affect the performance of the HPI algorithm in predicting hypotension in the PACU and ICU. Future research should evaluate the feasibility and influence on hypotension and outcomes following HPI implementation in non-ventilated patients at risk of hypotension.
More Related Videos
08:51Multiple Intravenous Bolus Dosing and Invasive Hemodynamic Assessment in a Hypoxia-Induced Mouse Pulmonary Artery Hypertension Model
Published on: November 11, 2022
07:48Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
Published on: October 28, 2022