Feasibility of Low-Dose and Low-Contrast Media Volume Approach in Computed Tomography Cardiovascular Imaging
Davide Ippolito1,2, Marco Porta2, Cesare Maino2
1Departement of Medicine and Surgery, University of Milano-Bicocca, Piazza OMS 1, 20100 Milano, Italy.
Abstract:
Aim: To evaluate the dose reduction and image quality of low-dose, low-contrast media volume in computed tomography (CT) examinations reconstructed with the model-based iterative reconstruction (MBIR) algorithm in comparison with the hybrid iterative (HIR) one. Methods: We prospectively enrolled a total of 401 patients referred for cardiovascular CT, evaluated with a 256-MDCT scan with a low kVp (80 kVp) reconstructed with an MBIR (study group) or a standard HIR protocol (100 kVp-control group) after injection of a fixed dose of contrast medium volume. Vessel contrast enhancement and image noise were measured by placing the region of interest (ROI) in the left ventricle, ascending aorta; left, right and circumflex coronary arteries; main, right and left pulmonary arteries; aortic arch; and abdominal aorta. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed. Subjective image quality obtained by consensus was assessed by using a 4-point Likert scale. Radiation dose exposure was recorded. Results: HU values of the proximal tract of all coronary arteries; main, right and left pulmonary arteries; and of the aorta were significantly higher in the study group than in the control group (p < 0.05), while the noise was significantly lower (p < 0.05). SNR and CNR values in all anatomic districts were significantly higher in the study group (p < 0.05). MBIR subjective image quality was significantly higher than HIR in CCTA and CTPA protocols (p < 0.05). Radiation dose was significantly lower in the study group (p < 0.05). Conclusions: The MBIR algorithm combined with low-kVp can help reduce radiation dose exposure, reduce noise, and increase objective and subjective image quality.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...