Related Experiment Video
Updated: Jul 2, 2025

Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
Foam control in lakes and sewage receiving water bodies: A pre-emptive approach using decentralized inline water
Reshmi Das1, Chanakya Hn1, Lakshminarayana Rao1
1Centre for Sustainable Technologies, Indian Institute of Science, Bengaluru, 560012, India.
Abstract:
Hideous and persistent foams on surface water bodies are global issues with far-reaching environmental consequences. This study examines Bellandur Lake (Bengaluru, India) plagued by foam since 2005 due to surfactant-laden untreated sewage ingress. Bellandur Lake receives 258 million liters of inadequately treated sewage daily, constituting 47% of its total volume. Yearlong water quality monitoring reveals that a) high surfactant levels (up to 17.8 ± 1 ppm) and b) prevalent anoxic conditions at lake inlets. Laboratory experiments show that controlled aeration achieved >90% surfactant degradation within 30 h at 3.5 ppm of dissolved oxygen conditions, indicating the need for an aeration chamber design based on the required residence time for inline water treatment. Based on these findings, a design of an inline wastewater treatment system to be installed at sewage entry points into the lake is presented in this work. The inline system was based on experimentally validated BioWin software. Simulations show that recirculating sludge enhances treatment efficiency, achieving effective surfactant degradation in 20 h (2/3rd original time) of residence time. Predictions suggest <1 ppm surfactant levels in the receiving water body, meeting local discharge norms to prevent frothing. This holistic approach, proposed for the first time, could serve as a blueprint for managing foam-related challenges in other waterbodies, offering insights into design, stakeholder engagement, and process optimization.
More Related Videos
08:17Coupling Carbon Capture from a Power Plant with Semi-automated Open Raceway Ponds for Microalgae Cultivation
Published on: August 14, 2020
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
Related Concept Videos
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Laminar Flow
Design Example: Analyzing Capacity Contours for Flood Risk Assessment