Related Experiment Video
Updated: Jul 2, 2025

Solid Phase 11C-Methylation, Purification and Formulation for the Production of PET Tracers
Published on: October 24, 2019
Multicenter Experience with Good Manufacturing Practice Production of [11C]PiB for Amyloid Positron Emission
Anders Bruhn Arndal Andersen1, Szabolcs Lehel2, Ebbe Klit Grove3
1Department of Nuclear Medicine, Copenhagen University Hospital, Herlev and Gentofte, Borgmester Ib Juuls Vej 1, 2730 Herlev, Denmark.
Abstract:
Alzheimer's disease (AD) is a neurodegenerative disorder with increasing global prevalence and accounts for over half of all dementia cases. Early diagnosis is paramount for not only the management of the disease, but also for the development of new AD treatments. The current golden standard for diagnosis is performed by positron emission tomography (PET) scans with the tracer [11C]Pittsburg Compound B ([11C]PiB), which targets amyloid beta protein (Aβ) that builds up as plaques in the brain of AD patients. The increasing demand for AD diagnostics is in turn expected to drive an increase in [11C]PiB-PET scans and the setup of new [11C]PiB production lines at PET centers globally. Here, we present the [11C]PiB production setups, experiences, and use from four Danish PET facilities and discuss the challenges and potential pitfalls of [11C]PiB production. We report on the [11C]PiB production performed with the 6-OH-BTA-0 precursor dissolved in either dry acetone or 2-butanone and by using either [11C]CO2 or [11C]CH4 as 11C- precursors on three different commercial synthesis modules: TracerLab FX C Pro, ScanSys, or TracerMaker. It was found that the [11C]CO2 method gives the highest radioactive yield (1.5 to 3.2 GBq vs. 0.8 ± 0.3 GBq), while the highest molar activity (98.0 ± 61.4 GBq/μmol vs. 21.2 to 95.6 GBq/μmol) was achieved using [11C]CH4. [11C]PiB production with [11C]CO2 on a TracerLab FX C Pro offered the most desirable results, with the highest yield of 3.17 ± 1.20 GBq and good molar activity of 95.6 ± 44.2 GBq/μmol. Moreover, all reported methods produced [11C]PiB in quantities suitable for clinical applications, thus providing a foundation for other PET facilities seeking to establish their own [11C]PiB production.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

