Related Experiment Video
Updated: Jul 2, 2025

Biofilm Removal Using Carbon Dioxide Aerosols without Nitrogen Purge
Published on: November 6, 2016
Disinfection of Bacteria in Aerosols by Applying High Voltage to Stranded Wire Electrodes
Takahisa Ueno1, Konosuke Takada2, Shohei Zaizen2
1Department of Electrical and Electronic Engineering, National Institute of Technology, Oita College, 1666 Maki, Oita-shi 870-0152, Japan.
Abstract:
The inactivation of airborne pathogenic microorganisms is crucial to attenuate the dissemination of infectious diseases induced by airborne pathogens. Conventional air disinfection methodologies, such as ultraviolet (UV) irradiation and ozone treatment, have demonstrated limited efficacy. Consequently, we investigated the potential of employing pulsed voltages to effectively eradicate bacteria within aerosols. Our inquiry revealed that the bacterial disinfection rate increased proportionally with elevated applied voltage and frequency. For instance, when a pulsed voltage of 20 kV and a frequency of 500 Hz were applied, a substantial disinfection rate exceeding 6.0 logarithmic units was attained. Furthermore, with the utilization of the stranded wire anodes, the disinfection intensity could be augmented by up to 2.0 logarithmic units compared with the solid wire configuration. Through the utilization of a stranded wire electrode model, we scrutinized the electric field encompassing the electrode, revealing a non-uniform electric field with the stranded wire electrode. This observation indicated an amplified bacterial disinfection effect, aligning with our experimental outcomes. These findings significantly enhance our comprehension of efficacious approaches to electrically disinfecting airborne bacteria.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Hand hygiene
Hand washing...
Atomic Emission Spectroscopy: Overview

