Mechanics of dynamic compression plate application in fracture fixation
Hwabok Wee1, Jacob Staub1, Zachary Koroneos1
1Department of Orthopaedics & Rehabilitation, Penn State College of Medicine, 500 University Drive, Hershey, PA 17033-0850, USA.
Background:
Dynamic compression plating is a fundamental type of bone fracture fixation used to generate interfragmentary compression. The goal of this study was to investigate the mechanics of the surgical application of these plates, specifically how plate prebend, screw location, fracture gap, and applied torque influence the resulting compressive pressures.
Methods:
Synthetic bones with transverse fractures were fixed with locking compression plates. One side of the fracture was fixed with locking screws. On the other side of the fracture, a nonlocking screw was inserted eccentrically to induce interfragmentary compression. A pressure mapping sensor within the fracture gap was used to record the resulting pressure distribution. Plate prebends of 0 mm, 1.5 mm, and 3 mm were tested. Three locations of the eccentric screw, four levels of screw torque, and two initial fracture gap conditions also were tested.
Findings:
With increasing plate prebend, fracture compression pressures shifted significantly toward the far cortex; however, compression force decreased (P < 0.05). The 1.5 mm prebend plate resulted in the greatest contact area. Increasing screw torque generally resulted in greater fracture compression force. The introduction of a 1 mm fracture gap at the far cortex prior to dynamic compression resulted in little or no fracture compression.
Interpretation:
The model showed that increasing plate prebend results in an increasing shift of fracture compression pressures toward the far cortex; however, this is accompanied by decreases in compressive force. Initial fracture gaps at the far cortex can result in little or no compression.
More Related Videos
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Applications of Stress
The...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...