Related Experiment Video
Updated: Jul 2, 2025

Ultrasound Assessment of Flow-Mediated Dilation of the Brachial and Superficial Femoral Arteries in Rats
Published on: November 3, 2016
Lower limb blood flow occlusion increases systemic pressor response without increasing brachial arterial blood flow
Abby R Fleming1, Hayley V MacDonald1, Samuel L Buckner2
1Department of Kinesiology, University of Alabama, Tuscaloosa, Alabama, USA.
Abstract:
This study was conducted to investigate the systemic hemodynamic and vascular changes in women during and after two commonly used clinical blood flow restriction (BFR) pressures at rest. There are minimal data regarding the independent effects of BFR on hemodynamic and systemic vascular changes due to pressor response, particularly among women. Therefore, this study investigated BFR-induced alterations in pressor response and systemic flow redistribution at rest during two commonly used pressures (50% and 80% limb occlusion pressure [LOP]). Fifteen women (22.1 ± 4.2 years) completed two randomised sessions involving 8-min of bilateral, lower limb restriction at 50% or 80% LOP followed by 8-min of recovery post-deflation. Changes in vascular (arterial diameter [DIA], time-averaged mean velocity [TAMV], volume flow [VF], and area) and hemodynamic (heart rate [HR] and blood pressure) measures over time (pre-, during, post-occlusion) and by session (50% vs. 80% LOP) were tested using repeated measures analysis of variance. Repeated measures correlations (rrm) quantified common intraindividual associations between BFR-induced hemodynamic and vascular responses. HR increased from baseline during 50% LOP and remained elevated during recovery (p < 0.05). HR increased from baseline during 80% LOP, while tibial VF and TAMV decreased (p < 0.03 for all). HR and TAMV values returned to baseline during recovery, while brachial artery VF decreased (p < 0.05). Changes in HR, brachial VF, and brachial TAMV were similar between 50% and 80% LOP (rrm = 0.32-0.70, p < 0.05 for all). At 80% LOP, changes in HR were positively correlated with brachial VF (rrm = 0.38) and TAMV (rrm = 0.43) and negatively correlated with tibial VF (rrm = -0.36) and TAMV (rrm = -0.30) (p < 0.05 for all). Results suggest that BFR at 80% LOP elicits an acute systemic pressor reflex without concomitant increases in brachial arterial flow, while 50% LOP elicits a subdued response.
More Related Videos
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Measurement of Blood Pressure