Occurrence of pseudoaneurysm of the coronary button due to aortic remodeling after Bentall operation
Takeyuki Kanemura1, Yoshinori Nakahara1, Retsu Tateishi1
1Department of Cardiovascular Surgery, IMS Katsushika Heart Center, 3-30-1 Horikiri, Katsushika Ward, Tokyo 124-0006, Japan.
Abstract:
Here, we present a case report detailing a pseudoaneurysm of the coronary button due to aortic remodeling that occurred 2 years after aortic root replacement. The patient was referred to our hospital with a diagnosis of left coronary artery pseudoaneurysm. Intraoperative findings revealed substantially loosened sutures in both the left and right coronary arteries with bleeding. Specifically, the left coronary artery was detached at the 6-9 o'clock positions. The operation was concluded with ligation of the loose suture and addition of a new suture. Chronic dissection thickened the aortic wall of the coronary artery ostium in the initial Bentall operation, whereas the sutured coronary button in this operation exhibited a normal arterial wall without a thickened dissected intima. This suggests that aortic wall remodelling of the coronary ostium leads to suture loosening and subsequent haemorrhage. Aortic wall remodeling may lead to bleeding or pseudoaneurysms during the remote period.