Related Experiment Video
Updated: Jul 2, 2025

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Comparative Analysis of Peak Air Pressure and Oxygen Flow between Conventional and Modified Endotracheal Tube for
1Department of Oral and Maxillofacial Surgery, School of Dental Sciences and Hospital, Krishna Vishwa Vidyapeeth Deemed to be University, Satara, Maharashtra, India.
Introduction:
In conventional practice for retromolar intubation, endotracheal tube (ET) is bent. This leads to compression of the inner diameter of the tube which in turn reduces airflow. Furthermore, conventionally ETs are stabilised in position using inflated tracheal cuff. Elastic sticky tapes around the exit pose hindrance for surgical procedures on the face. Surgical manipulation and maxillomandibular fixation may lead to compression, damage or accidental extubation of ET. We have developed a modified ET dedicated to retromolar intubation with innovative means for tube stabilisation to solve these problems.
Materials And Methods:
To study the efficacy of the tube, a comparative in vitro study was done on mannequins. Null hypothesis of no change in air pressure and oxygen concentration in bent conventional ET versus modified ET was formulated. Comparison was done on the basis of the peak air pressure (PEP) and oxygen concentration, which was checked using air-gas monitor.
Results:
The mean PEP was found to be 24.29 psi with standard deviation (SD) of 9.54 in sequentially bent conventional tube. This was found to be only 10.35 psi with SD of 3.22 in modified ET. Oxygen delivery was found to be 3.96 L/min in bent conventional tube, which was 5.22 L/min in modified tube. Both the findings were statistically significant.
Discussion:
Modified retromolar tube (PUNTUBE) has been found to be efficient in maintaining low PEP while delivering more oxygen as compared to bent conventional tube. Novel mode of tube stabilisation in the form of PUNSTAB is an easy and effective way of tube stabilisation.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...