Related Experiment Video
Updated: Jul 2, 2025

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Artificial Intelligence-Based Automated Interpretation of Images of Electrocardiograms: Development and Multinational
Akshay Khunte1,2, Veer Sangha1,3, Evangelos K Oikonomou1
1Section of Cardiovascular Medicine, Department of Internal Medicine, Yale School of Medicine, New Haven, CT.
Background:
Timely and accurate assessment of electrocardiograms (ECGs) is crucial for diagnosing, triaging, and clinically managing patients. Current workflows rely on computerized ECG interpretation tools built into ECG signal acquisition systems, which use rule-based algorithms that are unreliable and frequently not available in low-resource settings. We developed and validated a format-independent vision encoder-decoder model - ECG-GPT - that can generate free-text, expert-level interpretations directly from 12-lead ECG images.
Methods:
Using 12-lead ECGs and their corresponding diagnosis statements collected at the Yale-New Haven Health System (YNHHS) between 2000 and 2022, we developed a vision-text transformer model to generate interpretation statements from images of ECGs. Using structured clinical assessment, semantic similarity, and conventional natural language generation metrics, we validated ECG-GPT across 7 geographically distinct health settings. These include (1) 3 large and diverse US health systems, (2) consecutive ECGs from a central reading system in Minas Gerais, Brazil, (3) the prospective cohort study, UK Biobank, (4) a Germany-based, publicly available repository, PTB-XL, and (5) a community hospital in Missouri.
Results:
Overall, 2.9 million ECGs were used for model development. The model performed well in clinical assessment across 26 extracted labels: for atrial fibrillation, sinus tachycardia, sinus bradycardia, premature atrial contractions, and premature ventricular contractions, AUROCs and AUPRCs ranged from 0.80-0.95 and 0.50-0.86, respectively. For left bundle branch block, right bundle branch block, first degree atrioventricular block, left anterior fascicular block, and left posterior fascicular block, AUROCs and AUPRCs ranged from 0.88-0.96 and 0.23-0.86, respectively. Across all 26 conditions, diagnostic accuracy ranged between 0.93-0.99. ECG-GPT identified the full context of the diagnosis statements with allied conditions. It had a median pairwise cosine similarity of 0.90 (IQR 0.83-0.97), significantly greater than the median baseline similarity of 0.73 (IQR 0.67-0.78, p<0.001). This separation between median pairwise and baseline similarity remained consistent across all 26 condition-specific subsets. The results were comparable across external validation sites.
Conclusions:
We developed and extensively validated a vision encoder-decoder model that generates expert-level interpretations from ECG images. This represents a scalable and accessible strategy for automated ECG analysis, especially in low-resource settings.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....