Related Experiment Video
Updated: May 5, 2026

Using Retinal Imaging to Study Dementia
Published on: November 6, 2017
Deep Learning based Retinal Vessel Caliber Measurement and the Association with Hypertension
Shenshen Yan1, Jie Zhao2, Haicheng She1
1Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Science Key Lab, Beijing, China.
Purpose:
To develop a highly efficient and fully automated method that measures retinal vessel caliber using digital retinal photographs and evaluate the association between retinal vessel caliber and hypertension.
Methods:
The subjects of this study were from two sources in Beijing, China, a hypertension case-control study from Tongren Hospital (Tongren study) and a community-based atherosclerosis cohort from Peking University First Hospital (Shougang study). Retinal vessel segmentation and arteriovenous classification were achieved simultaneously by a customized deep learning model. Two experienced ophthalmologists evaluated whether retinal vessels were correctly segmented and classified. The ratio of incorrectly segmented and classified retinal vessels was used to measure the accuracy of the model's recognition. Central retinal artery equivalents, central retinal vein equivalents and arteriolar-to-venular diameter ratio were computed to analyze the association between retinal vessel caliber and the risk of hypertension. The association was then compared to that derived from the widely used semi-automated software (Integrative Vessel Analysis).
Results:
The deep learning model achieved an arterial recognition error rate of 1.26%, a vein recognition error rate of 0.79%, and a total error rate of 1.03%. Central retinal artery equivalents and arteriolar-to-venular diameter ratio measured by both Integrative Vessel Analysis and deep learning methods were inversely associated with the odds of hypertension in both Tongren and Shougang studies. The comparisons of areas under the receiver operating characteristic curves from the proposed deep learning method and Integrative Vessel Analysis were all not significantly different (p > .05).
Conclusion:
The proposed deep learning method showed a comparable diagnostic value to Integrative Vessel Analysis software. Compared with semi-automatic software, our deep learning model has significant advantage in efficiency and can be applied to population screening and risk evaluation.
More Related Videos
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
12:28Quantification of Vascular Parameters in Whole Mount Retinas of Mice with Non-Proliferative and Proliferative Retinopathies
Published on: March 12, 2022
Related Concept Videos
Measurement of Blood Pressure
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Hypertension II: Pathophysiology
Hypertension III: Clinical Manifestations and Diagnostic Studies
Diabetic Retinopathy