Related Experiment Video
Updated: May 6, 2026

Use of a Hanging Weight System for Coronary Artery Occlusion in Mice
Published on: April 19, 2011
The active pulling technique to solve microcatheter-uncrossable lesions in retrograde chronic total occlusion
Hongmin Zhu1,2, Xinyong Cai2, Yuliang Zhan2
1Jiangxi Medical College, Nanchang University, Nanchang, 330046, Jiangxi, China.
Background:
It is not uncommon to encounter retrograde microcatheter-uncrossable lesions in retro-recanalization of Chronic Total Occlusion (CTO) cases, existing solutions were time-consuming or complicated to operate. Therefore, the present study aimed to propose and evaluate the feasibility, safety of a novel technique termed Active Pulling retrograde microcatheter crossing Technique (APT) during retrograde CTO percutaneous coronary intervention (PCI).
Methods:
We retrospectively collected retrograde CTO-PCI cases from February 2017 to April 2023, only cases with the retrograde wire successfully crossed the CTO lesion were analyzed. The baseline clinical characteristics, angiographic characteristics, procedural details, and in-hospital major adverse cardiac events (MACEs) were compared.
Results:
A total of 80 CTO cases were divided into the APT group and the non-APT group according to whether the APT was applied in the procedure. The APT group had a higher rate of device success than the non-APT group (100% vs. 85%, P = 0.013), with shorter duration (5.3 ± 3.8 vs. 18.6 ± 5.9 min, P < 0.001) and a smaller number of retrograde microcatheters were used (P < 0.001). In the APT group, the average air kerma radiation exposure was lower (2.7 ± 1.2 vs. 4.3 ± 1.7 Gy, P < 0.001), the fluoroscopy time (69.0 ± 15.0 vs. 88.1 ± 18.9 min, P < 0.001) and the procedure time (116.2 ± 22.2 vs. 131.6 ± 28.7 min, P = 0.009) was shorter than the non-APT group. The technical success rate of both groups reached 100% while the procedure success rate was higher in the APT group than the non-APT group (100% vs. 85%, P = 0.13).
Conclusions:
The APT is an easy and safe technique that can greatly improve procedural efficiency without adding other instruments, and allows the retrograde microcatheter to quickly crossing the CTO body after successful retrograde wire externalization.