Related Experiment Video
Updated: Jul 2, 2025

Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
Observation of Large, Charged Droplet Signatures within the High-Vacuum Region of a Commercial Electrospray TOF-MS
Chris Heintz1, Lisa Schnödewind1, Oliver Braubach1
1Department of Physical and Theoretical Chemistry, University of Wuppertal, Gaussstraße 20, 42119 Wuppertal, Germany.
Abstract:
Electrospray ionization (ESI) is one of the most prominent atmospheric pressure ionization techniques in modern mass spectrometry. It generates charged droplets from an analyte-containing solution as an initial step in the ionization process. Textbooks and the majority of the articles assume the entire droplet evaporation and release of bare analyte ions within the ionization chamber. However, non-mass-spectrometry-related literature and recent reports demonstrate droplet observation in regions of the vacuum systems of a variety of mass spectrometers. In this work, we report on the observation of large droplet fragments within the orthogonal acceleration stage of a Bruker micrOTOF by connecting an oscilloscope to an auxiliary ion current detector downstream of the acceleration stage. Moreover, we detected fragment debris even with the MCP TOF detector by evaluating individual TOF spectra. Droplet fragments appear as pronounced and intensive pulses of the ion current. This observation is clearly connected to ESI, as other atmospheric pressure ionization methods do not show this behavior. The recorded droplet signatures show clear dependencies on the ion source and transfer stage parameters. The existence of large and highly charged droplets may adversely affect or at least impact the analytical performance of the instrument due to space charge or complex heterogeneous chemical reactions. Furthermore, the penetration of large charged aggregates into the vacuum system explains the reported surface contamination after multipole stages. This contamination of critical components leads to substantially higher maintenance efforts.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Analyzers: Common Types
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Overview

