Abstract:
Diastolic/systolic blood pressure ratio (D/S) ≥ 1.2 is the gold standard of enhanced external counterpulsation (EECP) treatment, but it does not show a clear clinical correspondence with the configuration of the EECP mode. As such, a single target results in different treatment effects in different individuals. The local haemodynamic effect (wall shear stress, WSS) of EECP on vascular endothelial cells is conducive to promote the growth of collateral circulation vessels and restore the blood supply distal to the stenosis lesion. Considering the haemodynamic effects of WSS on human arteries, this study developed a real-time patient-specific treatment strategy of EECP for patients with cardio-cerebrovascular diseases. Based on patient-specific haemodynamic data from 113 individuals, an optimization algorithm was developed to achieve the individualization of a 0D lumped-parameter model of the human circulatory system, thereby simulating the patient-specific global haemodynamic effects. 0D/3D coupled cardio-cerebrovascular models of two subjects were established to simulate the local WSS. We then established statistical models to evaluate clinically unmeasurable WSS based on measurable global haemodynamic indicators. With the aim of attaining appropriate area- and time-averaged WSS (ATAWSS, 4-7 Pa), as evaluated by global haemodynamic indicators, a closed-loop feedback tuning method was developed to provide patient-specific EECP treatment strategies. Results showed that for clinical data collected from 113 individuals, the individualized 0D model can accurately simulate patient-specific global haemodynamic effects (average error <5%). Based on two subjects, the statistical models can be used to evaluate local ATAWSS (error <6%) for coronary arteries and for cerebral arteries. An EECP mode planned by the patient-specific treatment strategy can promote an appropriate ATAWSS within a 16 s calculation time. The real-time patient-specific treatment strategy of EECP is expected to improve the long-term outcome for each patient and have potential clinical significance.
More Related Videos
04:42Treating Low Back Pain in Failed Back Surgery Patients with Multicolumn-lead Spinal Cord Stimulation
Published on: June 26, 2018
10:08The Evoked Potential Operant Conditioning System EPOCS: A Research Tool and an Emerging Therapy for Chronic Neuromuscular Disorders
Published on: August 25, 2022