Visual Evaluation of Plethysmographic Waveforms: Introducing the Simple Systolic Ratio as an Indicator of Fluid
Muhammet Selman Söğüt1, Kamil Darçın1, Muhammet Ahmet Karakaya2
1Koç University Hospital, Department of Anaesthesiology and Reanimation, İstanbul, Turkey.
Objective:
For patient safety, maintaining hemodynamic stability during surgical procedures is critical. Dynamic indices [such as systolic pressure variation (SPV) and pulse pressure variation (PPV)], have recently seen an increase in use. Given the risks associated with such invasive techniques, there is growing interest in non-invasive monitoring methods-and plethysmographic waveform analysis. However, many such non-invasive methods involve intricate calculations or brand-specific monitors. This study introduces the simple systolic ratio (SSR), derived from pulse oximetry tracings, as a non-invasive method to assess fluid responsiveness.
Methods:
This prospective observational study included 25 adult patients whose SPV, PPV, and SSR values were collected at 30-min intervals during open abdominal surgery. The SSR was defined as the ratio of the tallest waveform to the shortest waveform within pulse tracings. The correlations among SSR, SPV, and PPV were analyzed. Additionally, anaesthesia specialists visually assessed pulse oximetry tracings to determine fluid responsiveness using the SSR method.
Results:
Strong correlations were observed between SSR and both SPV (r = 0.715, P < 0.001) and PPV (r = 0.702, P < 0.001). Receiver operator curve analysis identified optimal SSR thresholds for predicting fluid responsiveness at 1.47 for SPV and 1.50 for PPV. A survey of anaesthesia specialists using the SSR method to visually assess fluid responsiveness produced an accuracy rate of 83%.
Conclusion:
Based on the strong correlations it exhibits with traditional markers, SSR has great potential as a clinical tool, especially in resource-limited settings. However, further research is needed to establish its role, especially as it pertains to its universal applicability across monitoring devices.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure