Evaluating drug stability and sterility in single-dose vials when accessed with a closed system transfer device
James N Hopkins1, Michael Waldman2, Raghvendra Sahai2
1Vanderbilt University Medical Center, Nashville, TN, USA.
Closed system transfer devices maintain the sterility and stability of single-dose vials during repeated access. This finding supports extended vial use, potentially reducing drug wastage and healthcare costs.
Area of Science:
- Pharmaceutical Science
- Microbiology
- Healthcare Management
Background:
- Drug wastage presents a significant financial burden on healthcare systems, patients, and hospital networks.
- Implementing strategies to minimize drug waste can yield substantial positive impacts across healthcare.
- Concerns regarding drug wastage necessitate investigations into practices that may prolong medication usability.
Purpose of the Study:
- To evaluate the impact of repeated access using a closed system transfer device on the sterility of single-dose vials.
- To assess the chemical stability of drugs within single-dose vials after repeated access.
- To determine if extended use of single-dose vials is feasible, thereby reducing drug wastage.
Main Methods:
- Sterility testing was conducted following United States Pharmacopeia (USP) 71 standards.
- Simulated compounding tasks using growth media and a closed system transfer device were performed in a clinical setting.
- Stability testing involved high-performance liquid chromatography (HPLC) analysis of drug samples at various time points post-access, compared to freshly opened vials.
Main Results:
- No microbial growth was detected in the accessed test vials, indicating maintained sterility.
- Control vials demonstrated microbial growth as expected, validating the testing methodology.
- Drugs within the vials maintained chemical stability for up to 72 hours post-access, comparable to freshly opened vials.
Conclusions:
- Closed system transfer devices do not introduce microbial contamination into drug vials with repeated access for up to 7 days.
- Tested drugs exhibit equivalent chemical stability for up to 72 hours after vial access.
- This study provides a framework for healthcare facilities to assess the sterility and stability of single-dose vials accessed with closed system transfer devices, supporting potential drug wastage reduction.
More Related Videos
Related Concept Videos
Factors Affecting Dissolution: Drug Permeability, Stability and Stereochemistry
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...