Related Experiment Video
Updated: Jul 2, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Abbreviated Molecular Breast Imaging: Feasibility and Future Considerations
Santo Maimone1, Andrey P Morozov1, Haley P Letter1
1Mayo Clinic Florida, Department of Radiology, Jacksonville, FL, USA.
Objective:
Molecular breast imaging (MBI) is a supplemental screening modality consistently demonstrating incremental cancer detection over mammography alone; however, its lengthy duration may limit widespread utilization. The study purpose was to assess feasibility of an abbreviated MBI protocol, providing readers with mediolateral oblique (MLO) projections only and assessing performance in lesion detection and localization.
Methods:
Retrospective IRB-exempt blinded reader study administered to 5 fellowship-trained breast imaging radiologists. Independent reads performed for 124 screening MBI cases, half abnormal and half negative/normal. Readers determined whether an abnormality was present, side of abnormality, and location of abnormality (medial/lateral). Abnormal cases had confirmatory biopsy or surgical pathology; normal cases had imaging follow-up ensuring true negative results. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated to assess performance. A false negative result indicated that a reader failed to detect abnormal uptake; a false positive result indicated a reader incorrectly called an abnormality for a negative case. Tests for association included chi-square, Fisher-exact, and analysis of variance.
Results:
Mean reader performance for detecting abnormal uptake: sensitivity 96.8%, specificity 98.7%, PPV 98.8%, and NPV 96.9%. Accuracy in localizing lesions to the medial or lateral breast was 100%. There were no associations in reader performance with reader experience, reader technique, lesion morphology, or lesion pathology. Median lesion size was 1.0 cm (range: 0.4-8.0 cm). All readers correctly identified 97.7% (42/43) of lesions with malignant or elevated risk pathology.
Conclusion:
An abbreviated MBI protocol (MLO images only) maintained high accuracy in lesion detection and localization.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
08:42Using Multi-fluorinated Bile Acids and In Vivo Magnetic Resonance Imaging to Measure Bile Acid Transport
Published on: November 27, 2016