Irregularity of instantaneous gamma frequency in the motor control network characterize visuomotor and proprioceptive

Jihye Ryu1, Jeong Woo Choi2, Soroush Niketeghad1

  • 1Department of Neurosurgery, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, United States of America.

PubMed

Related Concept Videos

Hierarchy of Motor Control01:18

Hierarchy of Motor Control

The hierarchy of motor control refers to the different levels of organization and processing involved in controlling movement in the body. These levels range from higher cortical areas involved in planning and decision-making to lower spinal cord reflexes that respond automatically to external stimuli.
2.7K
Muscle Stimulation Frequency01:22

Muscle Stimulation Frequency

The contraction strength of muscles is regulated by motor neurons, which modulate the frequency of action potentials dispatched to the motor units based on the body's requirements. This process of varying the muscle stimulation frequency allows muscles to contract with a force that is precisely tailored to the needs of the moment, whether lifting a feather or a heavy box.
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
2.2K
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
109
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
92
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
111
Motor Unit Stimulation01:20

Motor Unit Stimulation

When the neuron of a motor unit fires an action potential, it triggers a series of events, leading to a twitch contraction in the muscle fibers. The process of excitation-contraction coupling is crucial in relaying the action potential to the muscle fibers.
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
1.6K