Related Experiment Video
Updated: Jul 2, 2025

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Soft tissue injury events associated with neural integrity monitoring endotracheal tubes: A MAUDE database analysis
Andrew Salib1, Ana L Melero Pardo2, Michael Z Lerner1
1Division of Otolaryngology, Department of Surgery, Yale University School of Medicine, New Haven, CT, United States of America.
Objective:
Neural integrity monitoring (NIM) endotracheal tubes are widely used to provide intraoperative monitoring of the recurrent laryngeal nerve during certain neck surgeries, especially thyroidectomy, in order to reduce the risk of nerve injury and subsequent vocal fold paralysis. The unique design of NIM tubes and the increased technical skill required for correct placement compared to standard endotracheal tubes may increase the risk of upper aerodigestive tract soft tissue injury. This study aims to describe adverse events related to NIM endotracheal tubes.
Study Design:
Retrospective cross-sectional study.
Setting:
The US Food and Drug Administration's MAUDE database (2010-2022); (Manufacturer and User Facility Device Experience).
Methods:
The MAUDE database was queried for reports of adverse events that resulted in patient soft tissue injury involving the use of endotracheal tubes approved by the Food and Drug Administration.
Results:
There were 28 reported soft tissue injuries, with all events being related to the NIM EMG family of endotracheal tubes manufactured by Medtronic Xomed, Inc. Overall, 24 were categorized as device-related adverse events, and 4 were unspecified in the event description. The most common soft tissue injuries were edema (n = 7) and perforation (n = 7), each accounting for 25 % of adverse events. The second most common injury type was laceration (n = 4), representing 14 % of all adverse events. Overall, 9 patients (32 %) in our cohort required a surgical intervention to treat their injuries, which consisted of 6 tracheotomies and 3 instances of suture repair.
Conclusions:
The most commonly reported types of soft tissue injury included edema and perforation, followed by laceration. Increased awareness of device-related patient injuries associated with NIM endotracheal tubes can be used to better inform surgeons and anesthesiologists during the process of intubation and surgical decision-making.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...