Related Experiment Video
Updated: Jul 2, 2025

Heterogeneity Mapping of Protein Expression in Tumors using Quantitative Immunofluorescence
Published on: October 25, 2011
Heterogeneity in Systematic Reviews of Medical Imaging Diagnostic Test Accuracy Studies: A Systematic Review
Samuel J White1, Qi Sheng Phua2, Lucy Lu2
1Adelaide Medical School Faculty of Health and Medical Sciences, University of Adelaide, Adelaide, South Australia, Australia.
Importance:
Systematic reviews of medical imaging diagnostic test accuracy (DTA) studies are affected by between-study heterogeneity due to a range of factors. Failure to appropriately assess the extent and causes of heterogeneity compromises the interpretability of systematic review findings.
Objective:
To assess how heterogeneity has been examined in medical imaging DTA studies.
Evidence Review:
The PubMed database was searched for systematic reviews of medical imaging DTA studies that performed a meta-analysis. The search was limited to the 40 journals with highest impact factor in the radiology, nuclear medicine, and medical imaging category in the InCites Journal Citation Reports of 2021 to reach a sample size of 200 to 300 included studies. Descriptive analysis was performed to characterize the imaging modality, target condition, type of meta-analysis model used, strategies for evaluating heterogeneity, and sources of heterogeneity identified. Multivariable logistic regression was performed to assess whether any factors were associated with at least 1 source of heterogeneity being identified in the included meta-analyses. Methodological quality evaluation was not performed. Data analysis occurred from October to December 2022.
Findings:
A total of 242 meta-analyses involving a median (range) of 987 (119-441 510) patients across a diverse range of disease categories and imaging modalities were included. The extent of heterogeneity was adequately described (ie, whether it was absent, low, moderate, or high) in 220 studies (91%) and was most commonly assessed using the I2 statistic (185 studies [76%]) and forest plots (181 studies [75%]). Heterogeneity was rated as moderate to high in 191 studies (79%). Of all included meta-analyses, 122 (50%) performed subgroup analysis and 87 (36%) performed meta-regression. Of the 242 studies assessed, 189 (78%) included 10 or more primary studies. Of these 189 studies, 60 (32%) did not perform meta-regression or subgroup analysis. Reasons for being unable to investigate sources of heterogeneity included inadequate reporting of primary study characteristics and a low number of included primary studies. Use of meta-regression was associated with identification of at least 1 source of variability (odds ratio, 1.90; 95% CI, 1.11-3.23; P = .02).
Conclusions And Relevance:
In this systematic review of assessment of heterogeneity in medical imaging DTA meta-analyses, most meta-analyses were impacted by a moderate to high level of heterogeneity, presenting interpretive challenges. These findings suggest that, despite the development and availability of more rigorous statistical models, heterogeneity appeared to be incomplete, inconsistently evaluated, or methodologically questionable in many cases, which lessened the interpretability of the analyses performed; comprehensive heterogeneity assessment should be addressed at the author level by improving personal familiarity with appropriate statistical methodology for assessing heterogeneity and involving biostatisticians and epidemiologists in study design, as well as at the editorial level, by mandating adherence to methodologic standards in primary DTA studies and DTA meta-analyses.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Ultrasonography
During an ultrasonography procedure, a handheld device called...

