Pulse-wave analysis during routine blood pressure measurement shows potential to distinguish between sinus and
Chung-Chun Yang1, I-Ping Chan1, Tung Hsueh1
1Veterinary Medical Teaching Hospital, National Chung Hsing University, Taichung, Taiwan.
Objective:
To investigate whether pulse-wave analysis (PWA) performed by trained evaluators facilitates detection of nonsinus rhythm.
Animals:
Same-day, high-definition oscillometry pulse-wave data and ECG results of 155 animals (144 dogs and 11 cats) were analyzed.
Methods:
In this cross-sectional study, we enrolled 18 participants from various backgrounds, all of whom received PWA training. The ability to distinguish between sinus and nonsinus rhythms was assessed using receiver operating characteristic curve analysis. The pulse-wave datasets were divided into 5 ECG categories. Agreement between ECG diagnoses and PWA-based arrhythmia detection was evaluated using Cohen κ values, and the correlation between the academic year of veterinary students and their κ values was assessed.
Results:
All cardiology researchers demonstrated satisfactory accuracy in distinguishing pathological rhythms using PWA (area under the curve, 0.704 to 0.761), with the highest accuracy in detecting atrial fibrillation (area under the curve, 0.811 to 0.845). Fair agreement with ECG categorization was achieved by all 3 cardiology researchers, 2 of 5 general practitioners, and 3 of 10 veterinary undergraduates. The veterinary undergraduates' years of study were correlated with their diagnostic performance (Spearman ρ = 0.658; P = .019).
Clinical Relevance:
PWA during routine noninvasive blood pressure measurement showed significant potential for the detection of pathological arrhythmias, notably atrial fibrillation. This approach yielded improved effectiveness when it was used by veterinarians with cardiology experience. Thus, introducing hands-on training courses, particularly those focused on cardiology and interactive workshops, may enable frontline veterinarians to promptly identify arrhythmias using PWA, facilitating timely ECG examinations or referrals.
Related Concept Videos
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...