Related Experiment Video
Updated: Jul 1, 2025

Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Impact of Original and Artificially Improved Artificial Intelligence-based Computer-aided Diagnosis on Breast US
Wendie A Berg1,2, David Gur1, Andriy I Bandos3
1University of Pittsburgh School of Medicine, Department of Radiology, Pittsburgh, PA,USA.
Objective:
For breast US interpretation, to assess impact of computer-aided diagnosis (CADx) in original mode or with improved sensitivity or specificity.
Methods:
In this IRB approved protocol, orthogonal-paired US images of 319 lesions identified on screening, including 88 (27.6%) cancers (median 7 mm, range 1-34 mm), were reviewed by 9 breast imaging radiologists. Each observer provided BI-RADS assessments (2, 3, 4A, 4B, 4C, 5) before and after CADx in a mode-balanced design: mode 1, original CADx (outputs benign, probably benign, suspicious, or malignant); mode 2, artificially-high-sensitivity CADx (benign or malignant); and mode 3, artificially-high-specificity CADx (benign or malignant). Area under the receiver operating characteristic curve (AUC) was estimated under each modality and for standalone CADx outputs. Multi-reader analysis accounted for inter-reader variability and correlation between same-lesion assessments.
Results:
AUC of standalone CADx was 0.77 (95% CI: 0.72-0.83). For mode 1, average reader AUC was 0.82 (range 0.76-0.84) without CADx and not significantly changed with CADx. In high-sensitivity mode, all observers' AUCs increased: average AUC 0.83 (range 0.78-0.86) before CADx increased to 0.88 (range 0.84-0.90), P < 0.001. In high-specificity mode, all observers' AUCs increased: average AUC 0.82 (range 0.76-0.84) before CADx increased to 0.89 (range 0.87-0.92), P < 0.0001. Radiologists responded more frequently to malignant CADx cues in high-specificity mode (42.7% vs 23.2% mode 1, and 27.0% mode 2, P = 0.008).
Conclusion:
Original CADx did not substantially impact radiologists' interpretations. Radiologists showed improved performance and were more responsive when CADx produced fewer false-positive malignant cues.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...