Clinical value of foot thermometry in patients with acute limb ischemia
Dumitru Casian1,2, Alexandru Predenciuc1,2, Vasile Culiuc1,2
1Vascular Surgery Clinic, Department of General Surgery nr, 3, "Nicolae Testemitanu" State University of Medicine and Pharmacy, Chisinau, Moldova.
Objective:
We hypothesized that the severity of foot poikilothermy can be used for better differentiation of grades of acute limb ischemia. Thus, the study aim was evaluation of the value of non-contact foot thermometry, performed using a low-cost infrared medical thermometer, as an adjunct for clinical diagnosis of immediately threatened acute limb ischemia.
Methods:
It was a single-center observational prospective study performed over 3 years. Patients with acute limb ischemia of lower limbs grade I-IIB Rutherford treated with urgent revascularization were included. Grade of ischemia was determined independently by two experienced vascular surgeons. Thermometry of the ischemic foot was performed using a medical digital infrared non-contact thermometer (CK-T1501, Cooligg, China) with measuring accuracy of ±0.2°C. Temperature was measured in three points: the dorsal surface of the foot, plantar surface of the foot (both in the metatarsal region), and forehead. The maximal temperature gradient between patient's forehead and foot (∆Tmax F-F) was calculated. Measurements were repeated 6-12 h after revascularization.
Results:
A total of 147 patients were included. Only 3 (2%) patients presented rest pain without sensory loss and motor deficit, while the majority were diagnosed with mild (63/147, 42.8%) or moderate (27/147, 18.3%) motor deficit. The temperature of the ischemic foot varied from 20 to 36.1°C, while median value of the temperature was 26.7 [24.5-29.9] °C on the dorsal surface and 26.8 [24.5-29.6] °C on the plantar surface of the foot (p = 0.85). Patients with Grade IIB ischemia had significantly lower dorsal foot temperature, plantar foot temperature, and larger ∆Tmax F-F than the patients with grades I-IIA: 25.1 [23.9-26.8] °C versus 29.9 [27.6-30.8] °C; 25.2 [23.8-27.5] °C versus 29.6 [28-31.1] °C; and 11.6 [9.7-12.8] °C versus 7.2 [6-9] °C (p < 0.0001). Areas under ROC curve for diagnosis of Grade IIB ischemia were similar for dorsal foot temperature (0.82), plantar temperature (0.81), and ∆Tmax F-F (0.82). The best cutoff value by Youden was ≥9.5°C for ∆Tmax F-F, ≤26.8°C for dorsal, and ≤27.7°C for plantar temperature. Criterion ∆Tmax F-F offered the highest specificity of 86% (95%CI 74.2-93.7) and positive predictive value of 89.2% (95%CI 79.5-93.2), while plantar temperature offered sensitivity of 82.5% (95%CI 70.1-91.3) and negative predictive value of 69.1% (95%CI 57.6-83.2). In multivariate analysis including age, gender, and etiology of arterial occlusion, the criterion ∆Tmax F-F of ≥9.5°C was a unique variable significantly associated with risk of amputation (adjusted OR 2.6, 95%CI 1.2-5.9, p = 0.01).
Conclusion:
Current study demonstrated that patients with immediately threatening ALI have significantly lower foot temperature than those with viable and marginally threatened limbs. Severe foot poikilothermy at admission is associated with poor outcomes of revascularization, mostly with limb loss.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pulse Assessment Sites
Decreased Body Temperature
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...