Related Experiment Video
Updated: Jul 1, 2025

Transdermal Measurement of Glomerular Filtration Rate in Mice
Published on: October 21, 2018
Comparison of estimated GFR using cystatin C versus creatinine in pediatric kidney transplant recipients
Helen Pizzo1, John Nguyen2, George J Schwartz3
1Department of Pediatrics, Cedars-Sinai Medical Center, 8700 Beverly Blvd., Los Angeles, CA, 90048, USA. Helen.Pizzo@cshs.org.
Background:
An accurate, rapid estimate of glomerular filtration rate (GFR) in kidney transplant patients affords early detection of transplant deterioration and timely intervention. This study compared the performance of serum creatinine (Cr) and cystatin C (CysC)-based GFR equations to measured GFR (mGFR) using iohexol among pediatric kidney transplant recipients.
Methods:
CysC, Cr, and mGFR were obtained from 45 kidney transplant patients, 1-18 years old. Cr- and CysC-estimated GFR (eGFR) was compared against mGFR using the Cr-based (Bedside Schwartz, U25-Cr), CysC-based (Gentian CysC, CAPA, U25-CysC), and Cr-CysC combination (CKiD Cr-CysC, U25 Cr-CysC) equations in terms of bias, precision, and accuracy. Bland-Altman plots assessed the agreement between eGFR and mGFR. Secondary analyses evaluated the formulas in patients with biopsy-proven histological changes, and K/DOQI CKD staging.
Results:
Bias was small with Gentian CysC (0.1 ml/min/1.73 m2); 88.9% and 37.8% of U25-CysC estimations were within 30% and 10% of mGFR, respectively. In subjects with histological changes on biopsy, Gentian CysC had a small bias and U25-CysC were more accurate-both with 83.3% of and 41.7% of estimates within 30% and 10% mGFR, respectively. Precision was better with U25-CysC, CKiD Cr-CysC, and U25 Cr-CysC. Bland-Altman plots showed the Bedside Schwartz, Gentian CysC, CAPA, and U25-CysC tend to overestimate GFR when > 100 ml/min/1.72 m2. CAPA misclassified CKD stage the least (whole cohort 24.4%, histological changes on biopsy 33.3%).
Conclusions:
In this small cohort, CysC-based equations with or without Cr may have better bias, precision, and accuracy in predicting GFR.
Related Concept Videos
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...

