Related Experiment Video
Updated: Jul 1, 2025

Experimental Protocol to Investigate Particle Aerosolization of a Product Under Abrasion and Under Environmental Weathering
Published on: September 16, 2016
The relationship between the microclimate and efflorescence of revealed mural paintings and the later protection
Shiqiang Fang1, Wenjing Hu2, Qian Li3
1Centre for the Protection of Cultural Property, Ningbo University of Finance & Economics, Ningbo 315175, PR China; Department of Cultural Heritage and Museology, Zhejiang University, Hangzhou 310028, PR China.
Abstract:
Throughout history, there were many fine mural paintings concealed within ancient buildings, hidden beneath layers of plaster, wall or other structure. In recent decades, research and practical efforts had primarily focused on nondestructive diagnosis of these hidden murals and the removal of their surface coverings. However, limited attention had been given to the consequences of overlay removal on mural preservation. This study aims to address this gap by examining the revealed mural paintings in the Prince Shi's Palace as a case study, employing an analysis of mural ontology, investigation into the preservation environment, and simulation experiments to comprehensively analyze the factors contributing to the rapid deterioration of these revealed murals. The findings indicated that certain carbonated lime particles adhered to the mural surface, and in a humid environment, these particles absorbed sulfur dioxide from the atmosphere and converted into calcium sulfate. The strong hygroscopic property of calcium sulfate enhanced the humidity on the surface of murals, thereby increasing their susceptibility to sulfur dioxide absorption. Over time, the murals suffered more sulphate and moisture damage. Additionally, historically inaccurate interventions such as non-breathable shading curtains installation and organic coatings reinforcement exacerbated this deterioration process. Therefore, safeguarding the integrity of these exposed concealed murals necessitated prioritizing the preservation of environmental humidity and acid gas levels.
Related Concept Videos
Efflorescence in Masonry
While initial efflorescence is common post-construction and can be cleaned with water and a brush, in certain instances, efflorescence can reappear and gradually diminish over time as salts are leached out...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Mortar Joint Deterioration in Masonry
The...
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Frost Action on Concrete
This freeze-thaw cycle primarily causes surface scaling, where...

