Related Experiment Video
Updated: Aug 11, 2026

Single Cell Measurement of Dopamine Release with Simultaneous Voltage-clamp and Amperometry
Published on: November 21, 2012
A simple and accurate ratiometric sensor for determination of dopamine based on dual-emission carbon dots
Yuecheng Zhang1, Lingbo Sun2, Chengjia Li1
1College of Chemistry and Chemical Engineering, Key Laboratory of Analytical Technology and Detection of Yan'an, Yan'an University, Yan'an, 716000, Shaanxi, People's Republic of China.
Abstract:
Dopamine (DA) is a neuromodulatory molecule that plays critical roles in many biological processes. The dysfunctions of the DA system are closely associated with several nervous system diseases. Therefore, it is urgent to establish a simple and accurate method for DA analysis. In this study, an economic and accurate DA ratiometric sensor was established using dual-emission carbon dots (DE-CDs). DE-CDs were first synthesized by the one-step solvothermal method and two separate fluorescence emission peaks at 340 and 500 nm were observed under the excitation of 310 nm. In the presence of Hg2+, the fluorescence signal at 340 nm was significantly quenched, while the signal at 500 nm keeps stable. Upon adding DA, the quenched signal at 340 nm was significantly recovered, whereas the signal at 500 nm remains stable. Therefore, a novel ratiometric sensor for DA analysis was established. This method shows a good linear range from 500 nM to 100 μM, and the detection limit was calculated to be 80 nM. Moreover, this established method shows excellent specificity and could be applied in real sample analysis, showing great potential for application in clinical research.
Related Concept Videos
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II

