Related Experiment Video
Updated: Jul 1, 2025

Multiplexing Focused Ultrasound Stimulation with Fluorescence Microscopy
Published on: January 7, 2019
An implementation of class D inverter for ultrasonic transducer mixed powder mixture
Abstract:
Ultrasonic transducers (UTs) are the main components for generating sonic waves. These types of transducers are nonlinear loads, and they are adversely affected by changes in mechanical load or temperature. UTs are operated in the region close to the resonant frequency. An ultrasonic transducer needs to be driven by a high-frequency inverter. In this paper, a Class D resonant inverter circuit is implemented for ultrasonic mixer application. The proposed circuit operates at 34306 Hz at 140 V and has low cost and size. The simulation results of Class D inverter verified with the prototype experimental circuit. Al (Aluminum) alloy with ethanol and graphene is mixed in order to show the mixing performance of the resonant inverter fed transducer with probe. The system achieved the fine particles and homogen mixture according to the SEM images and EDX analysis.
More Related Videos
08:28Synthesis of Phase-shift Nanoemulsions with Narrow Size Distributions for Acoustic Droplet Vaporization and Bubble-enhanced Ultrasound-mediated Ablation
Published on: September 13, 2012
08:19Controllable Nucleation of Cavitation from Plasmonic Gold Nanoparticles for Enhancing High Intensity Focused Ultrasound Applications
Published on: October 5, 2018
Related Concept Videos
Voltage Doubler Circuit
Full wave rectifier