Related Experiment Video
Updated: Jul 1, 2025

Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Orthogonal retrieval algorithm of atmospheric temperature profiles from pure rotational Raman lidar signals
Abstract:
Aimed at the stability of calibration coefficients in a general non-orthogonal retrieval algorithm (NRA) of pure rotational Raman lidars (PRRLs), an orthogonal retrieval algorithm (ORA) of atmospheric temperature profiles based on the orthogonal basis function is proposed. This algorithm eliminates the correlation between the calibration coefficients in the NRA to reduce the influence of the number of calibration points and the selection scheme on the calibration coefficients. In this paper, the stabilities of calibration coefficients in the NRA and ORA are compared and analyzed, and the data analysis for atmospheric temperature profiles with a time resolution of minute-level are given, based on the developed Cloud Precipitation Potential Evaluation (CPPV) lidar data and the parallel radiosonde temperature data. The analysis results show that coefficients of variation (CVs) of ORA calibration coefficients are one order of magnitude smaller than those of NRA coefficients. The mean deviation of the ORA retrieval results is roughly reduced by 16.1% compared with the NRA, and the root-mean-square deviation is roughly reduced by 15.0% compared with the NRA. Therefore, the temperature retrieval performance of the ORA is better than that of the NRA.
More Related Videos
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
08:41A Rapid Laser Probing Method Facilitates the Non-invasive and Contact-free Determination of Leaf Thermal Properties
Published on: January 7, 2017
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...