Related Experiment Video
Updated: May 3, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Wide-field illumination diffuse optical tomography within a framework of single-pixel time-domain spatial frequency
Abstract:
We present a wide-field illumination time-domain (TD) diffusion optical tomography (DOT) for three-dimensional (3-D) reconstruction within a shallow region under the illuminated surface of the turbid medium. The methodological foundation is laid on the single-pixel spatial frequency domain (SFD) imaging that facilitates the adoption of the well-established time-correlated single-photon counting (TCSPC)-based TD detection and generalized pulse spectrum techniques (GPST)-based reconstruction. To ameliorate the defects of the conventional diffusion equation (DE) in the forward modeling of TD-SFD-DOT, mainly the low accuracy in the near-field region and in profiling early-photon migration, we propose a modified model employing the time-dependent δ-P1 approximation and verify its improved accuracy in comparison with both the Monte Carlo and DE-based ones. For a simplified inversion process, a modified GPST approach is extended to TD-SFD-DOT that enables the effective separation of the absorption and scattering coefficients using a steady-state equivalent strategy. Furthermore, we set up a single-pixel TD-SFD-DOT system that employs the TCSPC-based TD detection in the SFD imaging framework. For assessments of the reconstruction approach and the system performance, phantom experiments are performed for a series of scenarios. The results show the effectiveness of the proposed methodology for rapid 3-D reconstruction of the absorption and scattering coefficients within a depth range of about 5 mean free pathlengths.
More Related Videos
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...