Related Experiment Video
Updated: Jul 1, 2025

Implementation of a Reference Interferometer for Nanodetection
Published on: April 26, 2014
Synchronous filtering method for improving the optical signal-to-noise ratio of a tunable laser based on the
Abstract:
Optical measurements are closely related to the optical signal-to-noise ratio (OSNR) of the laser, which can be improved using a tunable optical filter (TOF) to suppress frequency noise. For an external-cavity tunable laser with a tuning range larger than the TOF bandwidth, the wavelength at the center of the TOF passband must be varied based on the laser tuning. This study proposes a tunable-laser OSNR-enhancement method based on the Fabry-Pérot (FP) interferometer. The FP signal contains the wavelength information of the swept laser, which can be used to determine the real-time driving voltage of the TOF. Notably, the laser needs to be continuously tunable without mode hopping, and the free spectral range of the FP interferometer must be smaller than the TOF bandwidth.