Short circuit faults are a prevalent issue in power systems, causing disruptions to the grid's normal operation. Dynamic behaviours of the conventional power systems during short circuit faults have been extensively studied and understood. The bulk of ongoing research and development are focusing on the dynamic performance of grid-connected renewable energy systems under these fault conditions, due to changes in the grid code and a decrease in system inertia. The development of effective control strategies to enhance the system's reliability during fault conditions is of paramount importance. In this paper, a two-stages grid-connected photovoltaic system (GCPV) having a rated power of 2 MW was created in the MATLAB/Simulink environment. The dynamic behaviour of the presented system was evaluated in two scenarios: steady state conditions and short circuit faults. A line-to-ground short circuit fault was created at the grid side, and its effect on the PV system's operation was observed. An advanced control system was designed to maintain stability during fault conditions. The results demonstrated the efficiency of the designated control system in minimizing the effects of short circuit faults on the GCPV system's function, and restoring the system promptly after the fault was cleared. Furthermore, considering modifications in grid regulations, the low voltage ride through (LVRT) capability of the designed system was analysed and validated according to the UK standards. The Total Harmonic Distortion (THD) level at the common coupling point was also analysed for voltage and current, remaining below the acceptable level of 5% as specified in the IEEE Std. 519.
More Related Videos
09:19In Situ Monitoring of the Accelerated Performance Degradation of Solar Cells and Modules: A Case Study for CuIn,GaSe2 Solar Cells
Published on: October 3, 2018
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Control of Power Flow
Load-frequency control
Power System Three-Phase Short Circuits
Maximum Power Flow and Line Loadability
Generator Voltage Control
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by: