Assessing heart rate and blood pressure estimation from image photoplethysmography using a digital blood pressure
Suchin Trirongjitmoah1, Arphorn Promking1, Khanittha Kaewdang1
1Department of Electrical and Electronics Engineering, Faculty of Engineering, Ubon Ratchathani University, 85 Sathonlamark, Warinchamrab, Ubon Ratchathani 34190, Thailand.
Abstract:
This study presents a non-contact approach to measuring heart rate and blood pressure using an image photoplethysmography (iPPG) signal, and compares the results to those from an oscillometric blood pressure meter. Facial videos of 100 subjects were recorded via a webcam under ambient lighting conditions to extract iPPG signals. The results revealed a strong correlation between the heart rate derived from iPPG and that obtained from an oscillometric blood pressure meter. In addition, a continuous wavelet transform images with a 6-s duration were used as input for a custom convolutional neural network model, providing the most accurate blood pressure estimation. The proposed method received a grade A for diastolic and grade B for systolic blood pressure based on the British Hypertension Society's criteria. It also met the standards set by the Association for the Advancement of Medical Instrumentation. This non-contact framework shows promising potential for efficient screening purposes.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement