A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
Role of Video Head Impulse Test to Assess Noise Exposure
1Department of Otorhinolaryngology, Faculty of Medicine, Universiti Malaya, Jalan Universiti, Kuala Lumpur, Wilayah Persekutuan Kuala Lumpur 50603 Malaysia.
Abstract:
Noise exposure has been reported to exert numerous detrimental effects on the human population, although most research has centred around hearing damage. Vestibular and balance loss have been demonstrated among industrial workers, although reports on this are still scarce. Vestibular loss increases the risk of falls, especially among industrial workers who are at constant risk. Nonetheless, the ideal investigation tool to investigate vestibular function remains unknown. We aim to review the available literature to elucidate the effect of noise exposure on semicircular canals using a video head impulse test (vHIT). A literature search identified only three studies involving 137 patients (mean age: 44.4). Semicircular canal deficit was found in 50.4% of the included participants, with lateral canal predominantly affected (71%). We highlight the importance of assessing the effect of noise exposure on vestibular function, especially among those prone to occupation-related vestibular loss.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.