Related Experiment Video
Updated: Jul 1, 2025

Introduction to Solid Supported Membrane Based Electrophysiology
Published on: May 11, 2013
A rational study of transduction mechanisms of different materials for all solid contact-ISEs
Heba M Hashem1, A B Abdallah2,3
1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt. hebamaher89@mans.edu.eg.
Abstract:
The new era of solid contact ion selective electrodes (SC-ISEs) miniaturized design has received an extensive amount of concern. Because it eliminated the requirement for ongoing internal solution composition optimization and created a two-phase system with stronger detection limitations. Herein, the determination of venlafaxine HCl is based on a comparison study between different ion- to electron transduction materials (such as; multiwalled carbon nanotubes (MWCNTs), polyaniline (PANi), and ferrocene) and illustrating their mechanisms in their applied sensors. Their different electrochemical features (such as bulk resistance (Rb**), double-layer capacitance (Cdl), geometric capacitance (Cg), and specific capacitance (Cp)) were evaluated and discussed by using the Electrochemical Impedance Spectroscopy (EIS), Chronopotentiometry (CP), and Cyclic Voltammetry (CV) experiments. The results indicated that each transducer's influence on the proposed sensor's electrochemical characteristics is determined by their unique chemical and physical properties. The electrochemical features vary for different solid contact materials used in transduction mechanisms. The results confirm that the MWCNT sensor revealed the best electrochemical behavior with the potentiometric response of a near-Nernestian slope of 56.1 ± 0.8 mV/decade with detection limits of 3.8 × 10-6 mol/L (r2 = 0.999) and a low potential drift (∆E/∆t) of 34.6 µV/s. Also, the selectivity study was performed in the presence of different interfering species either in single or complex matrices. This demonstrates excellent selectivity, stability, conductivity, and reliability as a VEN-TPB ion pair sensor for accurately measuring VEN in its various formulations. The proposed method was compared to HPLC reported technique and confirmed no significant difference between them. So, the proposed sensors fulfill their solutions' demand features for VEN appraisal.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Mechanically-gated Ion Channels
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several...
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...

