Stability of standardized uptake values for quantitative bone SPECT for jawbone lesions: a single-center
Hironobu Hata1,2, Satoshi Shimomura3, Kenji Imamachi4,5
1Department of Dentistry and Oral Surgery, NHO Hokkaido Cancer Center, Sapporo, Japan. hata.hironobu.wq@mail.hosp.go.jp.
Background:
The long time required for bone uptake of radiopharmaceutical material after injection for bone scintigraphy is a burden for patients with poor health. Thus, to assess whether the uptake time could be reduced for single-photon emission computed tomography (SPECT) of the jawbone, this study evaluated differences in maximum standardized uptake values (SUVmax) within patients using SPECT imaging at 2 and 3 hours after radiopharmaceutical injection.
Methods:
A total of 33 patients undergoing treatment or in post-treatment follow-up for medication-related osteonecrosis of the jaw, who visited our hospital between July 2020 and August 2021 and could receive SPECT twice on the same day, were enrolled in the study. Patients were injected with technetium-99 m hydroxymethylene diphosphonate (Tc-99 m HMDP) intravenously. The SUVmax for healthy parietal bones and jawbone lesions were calculated from the SPECT images using quantitative analysis software, and the SUVmax were compared between 2- and 3-hour uptake times.
Results:
After exclusion, 30 patients were included in the study. In the 2-hour and 3-hour images, the median SUVmax of the parietal bones were 1.90 and 1.81, respectively, and those of the jawbone lesions were 9.25 and 9.39, respectively. The limits of agreement (LOA) ranged from - 0.33 to 0.25 in the parietal bones, and the %LOA ranged from - 9.8 to 17.3% in the jawbone lesions, showing high equivalence between the two uptake durations. The SUVmax showed no clinical differences between the 2- and 3-hour uptake durations for Tc-99 m HMDP SPECT of the jawbone.
Conclusions:
The results of this study justify a 2-3-hour uptake window when performing quantitative SPECT of the jawbone. Therefore, the minimum uptake time can potentially be reduced to only 2 hours.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT