Removal of central venous catheter using Evolution® Rotating Dilator
Koichi Takamizawa1, Eriko Hasumi2, Katsuhito Fujiu2
1Department of Pediatrics, University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan.
Cardiology in the Young
|March 6, 2024
Abstract:
We experienced the first case of a difficult-to-extract central venous catheter removed with a pacemaker lead removal system: a 14-year-old boy with Hirschsprung's disease who had repeated catheter infections that could not be removed by traction. Because the catheter lumen was occluded, a suture was tied around the end of the catheter and the catheter was removed with a rotating dilator.
Keywords:
Central venous catheterEvolution® Rotating Dilatorpacemaker removal systempercutaneous removal