Related Experiment Video
Updated: Jul 1, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Development and evaluation of acceptance scale for artificial intelligence in digestive endoscopy by subjects
Xiuyan Long1, Haijun Deng2, Zinan Zhang3
1Department of Pediatrics, Third Xiangya Hospital, Central South University, Changsha 410013. 2070521987@qq.com.
Objectives:
Digestive endoscopy is an important diagnostic and therapeutic tool for digestive system diseases. The artificial intelligence (AI)-assisted system in endoscopy (hereinafter referred to as AI in digestive endoscopy) has broad application prospects in the field of digestive endoscopy. The trust and acceptance of endoscopic subjects are the cornerstone of the research, application, and promotion of AI in digestive endoscopy. Currently, the tools for measuring the acceptance of AI in digestive endoscopy by subjects are limited at home and abroad. This study aims to develop a scale for measuring the acceptance of AI in digestive endoscopy by subjects, then to evaluate its reliability and validity.
Methods:
By conducting literature research, an item pool and dimensions were constructed, and a preliminary scale was constructed using Delphi method. Through the first stage of the survey on the subjects, the reliability and validity of the scale were tested, and the revised scale was used for the second stage of survey on the subjects to further verify the structural validity of the scale.
Results:
The acceptance scale for AI in digestive endoscopy included 11 items in 3 dimensions: accuracy, ethics, benefit and willingness. In the first stage of the survey, 351 valid questionnaires were collected, and the Cronbach's α was 0.864. The correlation coefficient between the total score of the scale and the score of the test item was 0.636, and the Kaiser-Meyer-Olkin (KMO) value in exploratory factor analysis was 0.788. In the second stage of the survey, 335 valid questionnaires were collected, and in confirmatory factor analysis, the χ2/df was 3.774, while the root mean squared error of approximation (RMSEA) was 0.091.
Conclusions:
Acceptance scale for AI in digestive endoscopy by subjects developed in this study has good reliability and validity.
Related Concept Videos
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems...
Assessment of the Gastrointestinal System II: Health Perception Pattern
Health Perception Patterns
Health perception patterns offer valuable insights into a patient's lifestyle habits and how they may impact their GI health. These patterns include:
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures III: Video Capsule Endoscopy
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...

